{"id":273325,"date":"2024-10-19T18:21:38","date_gmt":"2024-10-19T18:21:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-83032018\/"},"modified":"2024-10-25T14:42:37","modified_gmt":"2024-10-25T14:42:37","slug":"bs-83032018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-83032018\/","title":{"rendered":"BS 8303:2018"},"content":{"rendered":"
This British Standard specifies requirements for the design and installation of the following types of domestic heating and cooking appliances, rated up to 50 kW, burning wood, woody biomass and solid fuels in both new and existing buildings (see Clause 6<\/b>):<\/p>\n open fires;<\/p>\n<\/li>\n room heaters;<\/p>\n<\/li>\n free-standing cookers; and<\/p>\n<\/li>\n independent boilers.<\/p>\n<\/li>\n<\/ol>\n The standard also specifies the procedures to be followed for on-site testing of the installations.<\/p>\n NOTE Where manufacturers\u2019 installation instructions are more onerous and give a higher level of safety, these take precedence over the requirements of this British Standard.<\/p>\n<\/blockquote>\n Installation of domestic heating and cooking appliances burning wood and solid mineral fuels. Specification<\/b><\/p>\n\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 7<\/td>\n Foreword <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 10<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 11<\/td>\n 4 Information and requirements to be agreed and documented
4.1 Information to be obtained by the installer
4.2 Checks before commencing work <\/td>\n<\/tr>\n\n 12<\/td>\n 4.3 Items for agreement
4.4 Appliance technical specifications and installation instructions
5 Appliance classification <\/td>\n<\/tr>\n\n 13<\/td>\n 6 General
6.1 Mechanical resistance and stability <\/td>\n<\/tr>\n\n 14<\/td>\n Figure 1 \u2014 Typical flue pipe entry to existing masonry chimney
6.2 Safety in case of fire <\/td>\n<\/tr>\n\n 15<\/td>\n 6.3 Air supply and connection to chimney
Table 1 \u2014 Air supply to solid fuel appliances <\/td>\n<\/tr>\n\n 18<\/td>\n 6.4 Safety in use <\/td>\n<\/tr>\n \n 19<\/td>\n Table 2 \u2014 Minimum flue size
6.5 Protection against noise <\/td>\n<\/tr>\n\n 20<\/td>\n 6.6 Energy economy and heat retention
7 Checking, handling and site storage of materials and components
7.1 Checking <\/td>\n<\/tr>\n\n 21<\/td>\n 7.2 Handling on site
7.3 Site storage
8 Coordination of work and installation preparation <\/td>\n<\/tr>\n\n 22<\/td>\n 9 Fireplace recess <\/td>\n<\/tr>\n \n 23<\/td>\n Figure 2 \u2014 Dimensions of a masonry-built fireplace recess <\/td>\n<\/tr>\n \n 24<\/td>\n Figure 3 \u2014 Construction of a fireplace recess (traditional brick construction)
10 Hearths
10.1 General <\/td>\n<\/tr>\n\n 25<\/td>\n 10.2 Constructional hearth
Figure 4 \u2014 Dimensions of a constructional hearth <\/td>\n<\/tr>\n\n 26<\/td>\n Figure 5 \u2014 Distance of an appliance from combustible material <\/td>\n<\/tr>\n \n 27<\/td>\n Figure 6 \u2014 Clearance between appliance and adjacent walls
Table 3 \u2014 Clearance between appliance and adjacent walls <\/td>\n<\/tr>\n\n 29<\/td>\n Figure 7 \u2014 Example of parallel installation with shielding of combustible wall <\/td>\n<\/tr>\n \n 30<\/td>\n Figure 8 \u2014 Example of angled installation with shielding of combustible wall (plan view)
10.3 Superimposed hearth <\/td>\n<\/tr>\n\n 31<\/td>\n Figure 9 \u2014 Positioning of appliance on a hearth (plan views) <\/td>\n<\/tr>\n \n 32<\/td>\n 10.4 Hearth for appliance placed or built into a raised fireplace recess <\/td>\n<\/tr>\n \n 34<\/td>\n Figure 10 \u2014 Hearth for appliance placed or built into a raised fireplace recess <\/td>\n<\/tr>\n \n 35<\/td>\n Table 4 \u2014 Dimensions for superimposed hearth below appliance on raised hearth
11 Connecting flue pipes
11.1 General
Figure 11 \u2014 Pipe or adaptor to flue
11.2 Size <\/td>\n<\/tr>\n\n 36<\/td>\n 11.3 Material
11.4 Installation <\/td>\n<\/tr>\n\n 37<\/td>\n Figure 12 \u2014 Vertical exit connection <\/td>\n<\/tr>\n \n 38<\/td>\n Figure 13 \u2014 Horizontal exit connection
11.5 Cleaning
11.6 Separation from combustible material <\/td>\n<\/tr>\n\n 39<\/td>\n Figure 14 \u2014 Separation from combustible material
11.7 Joints
12 Chimney and flue pipe cleaning
12.1 General <\/td>\n<\/tr>\n\n 40<\/td>\n 12.2 Soot door
Figure 15 \u2014 Typical installation of a free-standing cooker or independent boiler in a recess with a raft lintel <\/td>\n<\/tr>\n\n 41<\/td>\n Figure 16 \u2014 Typical installation of a free-standing cooker or independent boiler in an existing recess with metal register plate
12.3 Sweeping access in connecting flue pipe
12.4 Separation from combustible material <\/td>\n<\/tr>\n\n 42<\/td>\n Figure 17 \u2014 Typical free-standing rear outlet room heater fitted in a recess <\/td>\n<\/tr>\n \n 43<\/td>\n Figure 18 \u2014 Typical connection of a vertical outlet free-standing cooker or independent boiler to a chimney
13 Methods of closure at the top of a fireplace recess
13.1 Types and applications
13.2 Materials for closures at the top of a fireplace recess <\/td>\n<\/tr>\n\n 45<\/td>\n Figure 19 \u2014 Flue pipe connection to raft lintel
13.3 Installation of closures at the top of a fireplace recess <\/td>\n<\/tr>\n\n 47<\/td>\n Figure 20 \u2014 Securing of connecting flue pipe into register plate using clamping ring <\/td>\n<\/tr>\n \n 48<\/td>\n Figure 21 \u2014 Securing of connecting flue pipe into register plate using funnel adaptor <\/td>\n<\/tr>\n \n 49<\/td>\n 14 Fireback
14.1 General
14.2 Dimensions
14.3 Infill <\/td>\n<\/tr>\n\n 50<\/td>\n Figure 22 \u2014 Typical setting for inset open fire without a boiler <\/td>\n<\/tr>\n \n 51<\/td>\n Figure 23 \u2014 Typical installation of inset open fire with a boiler unit <\/td>\n<\/tr>\n \n 52<\/td>\n Figure 24 \u2014 Typical installation of a sunken ash pit inset open fire with underfloor air supply <\/td>\n<\/tr>\n \n 53<\/td>\n Figure 25 \u2014 Typical setting for inset open fire with convection, without boiler, installed into a BS 1251 fireback <\/td>\n<\/tr>\n \n 54<\/td>\n Table 5 \u2014 Composition proportion for in-fill
15 Fireplace surround
15.1 General
15.2 Mechanical fixing arrangements for fireplace surrounds
Figure 26 \u2014 Typical fixing brackets for cut stone surrounds <\/td>\n<\/tr>\n\n 56<\/td>\n Figure 27 \u2014 Typical fixing locations for cut stone surrounds
16 Throat <\/td>\n<\/tr>\n\n 57<\/td>\n 17 Boiler
18 Electrical supply
19 Open fires without convection
19.1 General
19.2 Inset open fire without boiler (see Figure 22)
19.3 Inset open fire with boiler (see Figure 23)
19.4 Inset open fire with underfloor air supply (see Figure 24) <\/td>\n<\/tr>\n\n 58<\/td>\n Figure 28 \u2014 Provision of permanent air vent openings in a solid floor <\/td>\n<\/tr>\n \n 59<\/td>\n 19.5 Inset open fire with fan-assisted air supply
20 Open fires with convection
20.1 General
20.2 Free-standing open fires <\/td>\n<\/tr>\n\n 60<\/td>\n Figure 29 \u2014 Construction of a fireplace recess (with a raft lintel) <\/td>\n<\/tr>\n \n 61<\/td>\n Figure 30 \u2014 Construction of a fireplace recess with corbelled gather applicable to a typical installation of inset open fires and room heaters <\/td>\n<\/tr>\n \n 62<\/td>\n Figure 31 \u2014 Typical open fire with convection fitted in a fireplace recess
20.3 Inset open fire with convection, with or without boiler <\/td>\n<\/tr>\n\n 63<\/td>\n Figure 32 \u2014 Inset convector open fire <\/td>\n<\/tr>\n \n 64<\/td>\n Figure 33 \u2014 Typical fitting of an open fire with convection to a back register plate
Figure 34 \u2014 Typical fitting and sealing of a free-standing room heater to a back register plate <\/td>\n<\/tr>\n\n 65<\/td>\n 21 Room heaters
21.1 General
21.2 Free-standing appliance in a fireplace recess <\/td>\n<\/tr>\n\n 66<\/td>\n Figure 35 \u2014 Typical free-standing room heater fitted in a recess
21.3 Inset appliance in a fireplace recess <\/td>\n<\/tr>\n\n 67<\/td>\n Figure 36 \u2014 Typical fitting of a closed inset appliance to a masonry\/clay lined chimney <\/td>\n<\/tr>\n \n 68<\/td>\n Figure 37 \u2014 Typical fitting of a closed inset appliance to a flexible stainless steel relined chimney <\/td>\n<\/tr>\n \n 69<\/td>\n 21.4 Inset (with or without boiler) installed in a free\u2011inset fireplace surround <\/td>\n<\/tr>\n \n 70<\/td>\n Figure 38 \u2014 Typical free inset application of room heater installation
22 Independent boilers and free-standing cookers
22.1 General <\/td>\n<\/tr>\n\n 71<\/td>\n 22.2 Appliance installed against a wall
22.3 Appliance installed in a fireplace recess
23 Making good <\/td>\n<\/tr>\n\n 72<\/td>\n 24 Carbon monoxide alarm
25 Commissioning of the installation
25.1 Inspection <\/td>\n<\/tr>\n\n 73<\/td>\n 25.2 Testing
26 Handover <\/td>\n<\/tr>\n\n 74<\/td>\n Annex A (informative)\u2002 Checklist for specifying purchaser\u2019s requirements
Figure A.1 \u2014 Checklist for specifying purchaser\u2019s requirements <\/td>\n<\/tr>\n\n 78<\/td>\n Annex B (informative)\u2002 Selection of appliances
Annex C (informative)\u2002 Assessing air permeability <\/td>\n<\/tr>\n\n 79<\/td>\n Annex D (normative)\u2002 Methods of checking flues and installations <\/td>\n<\/tr>\n \n 86<\/td>\n Annex E (informative)\u2002 Specifications of tested external air supply appliances <\/td>\n<\/tr>\n \n 87<\/td>\n Annex F (informative)\u2002 Risk assessment of external air supply appliances <\/td>\n<\/tr>\n \n 89<\/td>\n Annex G (informative)\u2002 Commissioning checklist
Table G.1 \u2014 Commissioning checklist: General <\/td>\n<\/tr>\n\n 90<\/td>\n Table G.2 \u2014 Commissioning checklist: Chimney details <\/td>\n<\/tr>\n \n 92<\/td>\n Table G.3 \u2014 Commissioning checklist: Hearth details
Table G.4 \u2014 Commissioning checklist: Appliance details <\/td>\n<\/tr>\n\n 93<\/td>\n Table G.5 \u2014 Commissioning checklist: Ventilation details <\/td>\n<\/tr>\n \n 94<\/td>\n Table G.6 \u2014 Commissioning checklist: Fuel storage details
Table G.7 \u2014 Commissioning checklist: Provision for maintenance <\/td>\n<\/tr>\n\n 95<\/td>\n Table G.8 \u2014 Commissioning checklist: Smoke tests <\/td>\n<\/tr>\n \n 96<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2018<\/td>\n 98<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":273331,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1332,2641],"product_tag":[],"class_list":{"0":"post-273325","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-97-100-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/273325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/273331"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=273325"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=273325"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=273325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}