{"id":308620,"date":"2024-10-19T21:10:54","date_gmt":"2024-10-19T21:10:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-16525-62014\/"},"modified":"2024-10-25T18:49:23","modified_gmt":"2024-10-25T18:49:23","slug":"bs-iso-16525-62014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-16525-62014\/","title":{"rendered":"BS ISO 16525-6:2014"},"content":{"rendered":"
This part of ISO 16525 specifies the pendulum-type test methods for impact strength of isotropic electrically conductive adhesives used in mounting components products on substrates.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Section sec_1 Section sec_2 Section sec_3 Section sec_3.1 Section sec_3.2 1\tScope 2\tNormative references 3\tTerms and definitions <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Section sec_3.3 Section sec_3.4 Section sec_3.5 Section sec_3.6 Section sec_3.7 Section sec_4 Section sec_5 Section sec_5.1 Section sec_5.2 4\tPrinciple 5\tTest apparatus and circuit 5.1\tBasic performance of the impact tester 5.2\tStructure of the hammer <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Figure fig_1 Section sec_5.3 5.3\tMeasurement with the hammer <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Figure fig_2 Section sec_5.4 Section sec_5.5 5.4\tScope of test 5.5\tStructure of the tester <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Table tab_c Figure fig_3 Section sec_5.6 Section sec_5.7 Section sec_5.7.1 5.6\tSpecimen-fixing stage 5.7\tMeasurement instruments <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Section sec_5.7.2 Section sec_5.7.3 Section sec_5.7.4 Section sec_6 Section sec_6.1 Section sec_6.2 Section sec_6.2.1 Section sec_6.2.2 Section sec_6.3 6\tSpecimen 6.1\tForm of specimens 6.2\tDimensions and tolerances of specimens 6.3\tStandard atmospheric conditions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Section sec_7 Section sec_7.1 Section sec_7.2 Section sec_8 Section sec_8.1 Section sec_8.2 7\tOperation 7.1\tLoading of specimen and position of impact 7.2\tConformance of specimen 8\tCalculation of impact strength 8.1\tCalculation \u2014 General 8.2\tCalculation of total impact energy <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Table tab_d Figure fig_4 <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Section sec_8.3 8.3\tCalculation of maximum force and maximum impact energy <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Table tab_g Figure fig_5 <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Table tab_h Figure fig_6 Section sec_8.4 Section sec_9 8.4\tChecking the fracture mode 9\tTest report <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Annex sec_A Annex sec_A.1 Annex sec_A.1.1 Annex sec_A.1.2 Table tab_i Figure fig_A.1 Annex sec_A.1.3 Annex\u00a0A \n(normative)<\/p>\n Example of preparation of specimens <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Annex sec_A.1.4 Table tab_j Figure fig_A.2 Annex sec_A.1.5 <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table tab_k Figure fig_A.3 Table tab_l Figure fig_A.4 <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex sec_A.1.6 Table tab_m Figure fig_A.5 Annex sec_A.2 Table tab_n Figure fig_A.6 <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex sec_B Annex sec_B.1 Annex\u00a0B \n(informative)<\/p>\n Correction of data <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Reference ref_1 Reference ref_2 Reference ref_3 Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Adhesives. Test methods for isotropic electrically conductive adhesives – Determination of pendulum-type shear impact<\/b><\/p>\n |