{"id":314306,"date":"2024-10-19T21:38:48","date_gmt":"2024-10-19T21:38:48","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-4266-32002\/"},"modified":"2024-10-25T19:45:23","modified_gmt":"2024-10-25T19:45:23","slug":"bs-iso-4266-32002","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-4266-32002\/","title":{"rendered":"BS ISO 4266-3:2002"},"content":{"rendered":"

This part of ISO 4266 gives guidance on the accuracy, installation, commissioning, calibration and verification of automatic level gauges (ALGs) both intrusive and non-intrusive, for measuring the level of petroleum and petroleum products having a vapour pressure less than 4 MPa, stored in pressurized storage tanks.<\/p>\n

This part of ISO 4266 gives guidance on the use of ALGs in custody transfer application.<\/p>\n

This part of ISO 4266 is not applicable to the measurement of level in caverns and refrigerated storage tanks with ALG equipment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nTitlePage – Petroleum and liquid petroleum products\ufffd\u2014 Measurement of level and temperature in sto… <\/td>\n<\/tr>\n
5<\/td>\nTableofContent – Contents Page <\/td>\n<\/tr>\n
7<\/td>\nForeword – Foreword <\/td>\n<\/tr>\n
9<\/td>\nScope – 1\ufffd\ufffd\ufffd Scope
NormativeReference – 2\ufffd\ufffd\ufffd Normative reference <\/td>\n<\/tr>\n
11<\/td>\nClause1 – 4\ufffd\ufffd\ufffd Precautions
Subclause2 – 4.1\ufffd\ufffd\ufffd Safety precautions
Subclause2 – 4.2\ufffd\ufffd\ufffd Equipment precautions
UntitledSubclause3 – 4.2.1\ufffd\ufffd\ufffd All of the ALG equipment should be capable of withstanding the pres…
UntitledSubclause3 – 4.2.2\ufffd\ufffd\ufffd ALGs should be certified for use in the hazardous-area classificati…
UntitledSubclause3 – 4.2.3\ufffd\ufffd\ufffd Measures should be taken to ensure that all exposed metal parts of …
UntitledSubclause3 – 4.2.4\ufffd\ufffd\ufffd All ALG equipment should be maintained in safe operating condition …
Subclause2 – 4.3\ufffd\ufffd\ufffd General precautions
UntitledSubclause3 – 4.3.1\ufffd\ufffd\ufffd The general precautions given in
UntitledSubclause3 – 4.3.2\ufffd\ufffd\ufffd The measurement of tank vapour pressure and temperature, liquid tem…
UntitledSubclause3 – 4.3.3\ufffd\ufffd\ufffd All data measured for bulk transfer should be recorded promptly whe…
UntitledSubclause3 – 4.3.4\ufffd\ufffd\ufffd Whenever determinations of the contents of a tank are made before t…
UntitledSubclause3 – 4.3.5\ufffd\ufffd\ufffd All parts of the ALG in contact with the product or its vapour shou…
UntitledSubclause3 – 4.3.6\ufffd\ufffd\ufffd ALGs should have sufficient dynamic response to track the liquid le…
UntitledSubclause3 – 4.3.7\ufffd\ufffd\ufffd Following the transfer of product, the tank should be allowed to se…
UntitledSubclause3 – 4.3.8\ufffd\ufffd\ufffd Following a rapid change in the ambient conditions, the liquid surf…
UntitledSubclause3 – 4.3.9\ufffd\ufffd\ufffd ALGs should provide security to prevent unauthorized adjustment or … <\/td>\n<\/tr>\n
12<\/td>\nClause1 – 5\ufffd\ufffd\ufffd Accuracy
Subclause2 – 5.1\ufffd\ufffd\ufffd Intrinsic error of ALGs
Subclause2 – 5.2\ufffd\ufffd\ufffd Calibration prior to installation
Subclause2 – 5.3\ufffd\ufffd\ufffd Error caused by installation and operating conditions
Subclause2 – 5.4\ufffd\ufffd\ufffd Overall accuracy
Subclause3 – 5.4.1\ufffd\ufffd\ufffd General <\/td>\n<\/tr>\n
13<\/td>\nSubclause3 – 5.4.2\ufffd\ufffd\ufffd Use of ALGs for fiscal\/custody transfer applications
Clause1 – 6\ufffd\ufffd\ufffd Installation of ALGs
Subclause2 – 6.1\ufffd\ufffd\ufffd General
Subclause2 – 6.2\ufffd\ufffd\ufffd Mounting location
UntitledSubclause3 – 6.2.1\ufffd\ufffd\ufffd The mounting location of an ALG may affect the installed accuracy. …
UntitledSubclause3 – 6.2.2\ufffd\ufffd\ufffd The ALG should preferably be mounted as close as practical to the v…
UntitledSubclause3 – 6.2.3\ufffd\ufffd\ufffd The level-sensing element should be protected against excessive tur…
Subclause2 – 6.3\ufffd\ufffd\ufffd Manufacturer\u2019s requirements
Subclause2 – 6.4\ufffd\ufffd\ufffd Installation
Subclause3 – 6.4.1\ufffd\ufffd\ufffd Installation of intrusive ullage ALGs (e.g. float-operated and servo-operat…
UntitledSubclause4 – 6.4.1.1\ufffd\ufffd\ufffd For fiscal\/custody transfer application accuracy, the ALG should …
UntitledSubclause4 – 6.4.1.2\ufffd\ufffd\ufffd For ease of maintenance and verification, the ALG should be insta…
Subclause3 – 6.4.2\ufffd\ufffd\ufffd Installation of intrusive ullage ALGs (e.g. float and servo-operated types)…
UntitledSubclause4 – 6.4.2.1\ufffd\ufffd\ufffd For fiscal\/custody transfer application accuracy and for operatio… <\/td>\n<\/tr>\n
16<\/td>\nUntitledSubclause4 – 6.4.2.2\ufffd\ufffd\ufffd For ease of maintenance and verification, the ALG should be insta…
Subclause3 – 6.4.3\ufffd\ufffd\ufffd Installation of non-intrusive ullage ALGs (e.g. microwave or radar) mounted…
UntitledSubclause4 – 6.4.3.1\ufffd\ufffd\ufffd For fiscal\/custody transfer application accuracy, and also for op…
UntitledSubclause4 – 6.4.3.2\ufffd\ufffd\ufffd A datum plate which may serve as a reflector plate (shown in
UntitledSubclause4 – 6.4.3.3\ufffd\ufffd\ufffd The construction of the ALG may not require the installation of a…
UntitledSubclause4 – 6.4.3.4\ufffd\ufffd\ufffd Adequate means should be provided (e.g. verification pins positio…
Subclause3 – 6.4.4\ufffd\ufffd\ufffd Location of ALG
Subclause3 – 6.4.5\ufffd\ufffd\ufffd Installation of ALGs other than those described in this part of ISO 4266
Subclause2 – 6.5\ufffd\ufffd\ufffd Still-well design
UntitledSubclause3 – 6.5.1\ufffd\ufffd\ufffd The still-well should be suspended from the top of the tank. The lo…
UntitledSubclause3 – 6.5.2\ufffd\ufffd\ufffd The diameter and thickness of the still-well should be designed to …
UntitledSubclause3 – 6.5.3\ufffd\ufffd\ufffd The distance from the lower end of the still-well to the bottom of …
UntitledSubclause3 – 6.5.4\ufffd\ufffd\ufffd The still-well perforations (slots or holes typically
UntitledSubclause3 – 6.5.5\ufffd\ufffd\ufffd After the tank has been hydrostatically tested, the still-well shou… <\/td>\n<\/tr>\n
18<\/td>\nClause1 – 7\ufffd\ufffd\ufffd Initial setting and initial verification of ALGs in the field
Subclause2 – 7.1\ufffd\ufffd\ufffd Preparation
Subclause3 – 7.1.1\ufffd\ufffd\ufffd Check for critical distances
Subclause3 – 7.1.2\ufffd\ufffd\ufffd Check for free movement of level-sensing element of intrusive ALGs
Subclause3 – 7.1.3\ufffd\ufffd\ufffd Check for influences of changes in physical and electrical properties of th…
Subclause2 – 7.2\ufffd\ufffd\ufffd Initial setting
Subclause3 – 7.2.1\ufffd\ufffd\ufffd General <\/td>\n<\/tr>\n
19<\/td>\nSubclause3 – 7.2.2\ufffd\ufffd\ufffd Setting of intrusive ullage ALGs
Subclause4 – 7.2.2.1\ufffd\ufffd\ufffd Setting of an intrusive ullage ALG (e.g. float- or servo-operated ALG) on…
Subclause4 – 7.2.2.2\ufffd\ufffd\ufffd Setting of an intrusive ALG (e.g. float- or servo-operated ALG) with the …
Subclause3 – 7.2.3\ufffd\ufffd\ufffd Setting of non-intrusive ALGs
Subclause4 – 7.2.3.1\ufffd\ufffd\ufffd Setting of a non-intrusive ALG (e.g. microwave or radar-based ALG) on an …
Subclause4 – 7.2.3.2\ufffd\ufffd\ufffd Setting of a non-intrusive ALG (e.g. microwave or radar-based ALG) with t… <\/td>\n<\/tr>\n
20<\/td>\nSubclause3 – 7.2.4\ufffd\ufffd\ufffd Other ALGs not described in this part of ISO\ufffd4266
Subclause2 – 7.3\ufffd\ufffd\ufffd Initial field verification
Subclause3 – 7.3.1\ufffd\ufffd\ufffd Introduction
Subclause3 – 7.3.2\ufffd\ufffd\ufffd Verification procedure
Subclause4 – 7.3.2.1\ufffd\ufffd\ufffd Rounding off
Subclause4 – 7.3.2.2\ufffd\ufffd\ufffd Procedure
Subclause4 – 7.3.2.3\ufffd\ufffd\ufffd Resetting or readjustment of an ALG during initial field verification <\/td>\n<\/tr>\n
21<\/td>\nSubclause3 – 7.3.3\ufffd\ufffd\ufffd Tolerance of initial field verification
Subclause2 – 7.4\ufffd\ufffd\ufffd Record keeping
Clause1 – 8\ufffd\ufffd\ufffd Subsequent verification of ALGs
Subclause2 – 8.1\ufffd\ufffd\ufffd General
Subclause2 – 8.2\ufffd\ufffd\ufffd Frequency of subsequent verification
Subclause2 – 8.3\ufffd\ufffd\ufffd Procedure
UntitledSubclause3 – 8.3.1\ufffd\ufffd\ufffd The liquid level at which the ALG is verified in a subsequent verif…
UntitledSubclause3 – 8.3.2\ufffd\ufffd\ufffd The subsequent verification can be performed by taking three consec…
UntitledSubclause3 – 8.3.3\ufffd\ufffd\ufffd For ALGs in fiscal\/custody transfer applications, the average ALG r…
Subclause2 – 8.4\ufffd\ufffd\ufffd Tolerance for subsequent verification of ALGs in fiscal\/custody transfer appl… <\/td>\n<\/tr>\n
22<\/td>\nSubclause2 – 8.5\ufffd\ufffd\ufffd Comparison of the ALG readings from current and previous verifications
UntitledSubclause3 – 8.5.1\ufffd\ufffd\ufffd For ALGs used in fiscal\/custody transfer application, the average A…
UntitledSubclause3 – 8.5.2\ufffd\ufffd\ufffd Compare the average ALG reading from the current verification again…
UntitledSubclause3 – 8.5.3\ufffd\ufffd\ufffd Compare the average ALG reading from the current verification again…
UntitledSubclause3 – 8.5.4\ufffd\ufffd\ufffd If any of the tolerances described in
Subclause2 – 8.6\ufffd\ufffd\ufffd Adjustment in subsequent verification
Clause1 – 9\ufffd\ufffd\ufffd Data communication and receiving <\/td>\n<\/tr>\n
23<\/td>\nBibliography – Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Petroleum and liquid petroleum products. Measurement of level and temperature in storage tanks by automatic methods – Measurement of level in pressurized storage tanks (non-refrigerated)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2002<\/td>\n24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":314312,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1081,2641],"product_tag":[],"class_list":{"0":"post-314306","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-75-180-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/314306","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/314312"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=314306"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=314306"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=314306"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}