{"id":315419,"date":"2024-10-19T21:44:21","date_gmt":"2024-10-19T21:44:21","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-ts-169962015\/"},"modified":"2024-10-25T19:52:48","modified_gmt":"2024-10-25T19:52:48","slug":"bsi-pd-iso-ts-169962015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-ts-169962015\/","title":{"rendered":"BSI PD ISO\/TS 16996:2015"},"content":{"rendered":"
This Technical Specification specifies the procedure for a determination of major and minor element concentrations in biomass material by energy dispersive X-ray fluorescence (EDXRF) spectrometry or wavelength dispersive X-ray fluorescence (WDXRF) spectrometry using a calibration with biomass reference materials. A semi-quantitative determination may be carried out using matrix independent standards.<\/p>\n
This Technical Specification is applicable for the following elements: Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Mo, Cd, Sb, and Pb. Concentrations from approximately 0,000 1 % and above can be determined depending on the element, the calibration materials used and the instrument used.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1\tScope 2\tNormative references 3\tTerms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4\tSafety remarks <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5\tSymbols and abbreviated terms 5.1\tSymbols 5.2\tAbbreviated terms 6\tPrinciple <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 7\tApparatus 8\tInterferences and sources of error <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 9\tSample preparation 9.1\tPreparation principles 9.2\tDrying of general analysis sample material 9.3\tPreparation of pressed pellet 10\tProcedure 10.1\tAnalytical measurement conditions 10.1.1\tWavelength dispersive instruments <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 10.1.2\tEnergy dispersive instruments <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 10.2\tCalibration 10.2.1\tGeneral <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 10.2.2\tGeneral calibration procedure 10.2.3\tCalibration procedure using the pressed pellet method (recommended method) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 10.3\tProcedures for correcting matrix effect 10.3.1\tInternal standard correction using Compton (incoherent) scattering method 10.3.2\tFundamental parameter approach 10.3.3\tFundamental or theoretical influence coefficient method <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 10.3.4\tEmpirical alpha correction <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 10.4\tAnalysis of the samples 11\tQuality control 11.1\tDrift correction procedure 11.2\tReference materials 12\tCalculation of the result <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 13\tPerformance characteristics 14\tTest report <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex\u00a0A (informative) Publicly available biomass reference materials <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Solid biofuels. Determination of elemental composition by X-ray fluorescence<\/b><\/p>\n |