{"id":326902,"date":"2024-10-19T22:42:05","date_gmt":"2024-10-19T22:42:05","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d6178-6\/"},"modified":"2024-10-25T21:22:56","modified_gmt":"2024-10-25T21:22:56","slug":"astm-d6178-6","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d6178-6\/","title":{"rendered":"ASTM-D6178"},"content":{"rendered":"<\/p>\n

1.1 This practice covers the procedures for estimation of short-term human inhalation exposure to volatile organic chemicals (VOCs) emitted from bedding sets when a new bedding set is first brought into a house.<\/p>\n

1.2 The estimated exposure is based on an estimated emission profile of VOCs from bedding sets.<\/p>\n

1.3 The VOC emission from bedding sets, as in the case of other household furnishings, usually are highest when the products are new. Procedures described in this practice also are applicable to used bedding sets.<\/p>\n

1.4 Exposure to airborne VOC emissions in a residence is estimated for a household member, based on location and activity patterns.<\/p>\n

1.5 The estimated exposure may be used for characterization of health risks that could result from short-term exposures to VOC emissions.<\/p>\n

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.<\/i><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Summary of Practice <\/td>\n<\/tr>\n
2<\/td>\nSignificance and Use
Procedures for Exposure Estimation <\/td>\n<\/tr>\n
3<\/td>\nReport
Keywords
X1. SUPPLEMENTAL MATERIAL
X1.1 Example Calculations for Bedroom and Bedding Set <\/td>\n<\/tr>\n
4<\/td>\nX1.2 Example of Location and Activity Patterns
X1.3 Example Calculations for Airflow Rate Between Vicin-ity of the Bedding Set and Remainder of the Bedroom
References <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D6178-97(2003) Standard Practice for Estimation of Short-Term Inhalation Exposure to Volatile Organic Chemicals Emitted from Bedding Sets<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2003<\/td>\n4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":326909,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[208,2637],"product_tag":[],"class_list":{"0":"post-326902","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-040-99","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/326902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/326909"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=326902"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=326902"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=326902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}