{"id":363450,"date":"2024-10-20T01:45:43","date_gmt":"2024-10-20T01:45:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-xi-2015\/"},"modified":"2024-10-26T02:45:31","modified_gmt":"2024-10-26T02:45:31","slug":"asme-bpvc-xi-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-xi-2015\/","title":{"rendered":"ASME BPVC XI 2015"},"content":{"rendered":"

None<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
54<\/td>\nIWA-1600-1 Referenced Standards and Specifications <\/td>\n<\/tr>\n
58<\/td>\nIWA-2211-1 Visual Examinations <\/td>\n<\/tr>\n
61<\/td>\nIWA-2322-1 Near-Distance Acuity Test Distances and Character Heights <\/td>\n<\/tr>\n
67<\/td>\nIWA-3310-1 Surface Planar Flaws Oriented in Plane Normal to Pressure-Retaining Surface <\/td>\n<\/tr>\n
68<\/td>\nIWA-3320-1 Subsurface Planar Flaws Oriented in Plane Normal to Pressure-Retaining Surface <\/td>\n<\/tr>\n
69<\/td>\nIWA-3320-2 Successive Examination Surface Proximity Rule for Class 1 and Class 2 Vessels <\/td>\n<\/tr>\n
70<\/td>\nIWA-3330-1 Multiple Planar Flaws Oriented in Plane Normal to Pressure-Retaining Surface <\/td>\n<\/tr>\n
71<\/td>\nIWA-3340-1 Nonplanar Elliptical Subsurface Flaws <\/td>\n<\/tr>\n
72<\/td>\nIWA-3350-1 Parallel Planar Flaws <\/td>\n<\/tr>\n
73<\/td>\nIWA-3360-1 Laminar Flaws <\/td>\n<\/tr>\n
74<\/td>\nIWA-3380-1 Nonaligned Coplanar Flaws in Plane Normal to Pressure-Retaining Surface <\/td>\n<\/tr>\n
75<\/td>\nIWA-3390-1 Multiple Aligned Planar Flaws (1\/2 in. = 13 mm) <\/td>\n<\/tr>\n
76<\/td>\nIWA-3400-1 Linear Surface Flaws <\/td>\n<\/tr>\n
87<\/td>\nIWA-4461.1-1 Minimum Preheat Temperature, \u00b0F (\u00b0C) <\/td>\n<\/tr>\n
92<\/td>\nIWA-4623.1-1 Temper Bead Welding and Weld Temper Bead Reinforcement <\/td>\n<\/tr>\n
93<\/td>\nIWA-4623.2-1 Automatic or Machine (GTAW) Temper Bead Welding <\/td>\n<\/tr>\n
95<\/td>\nIWA-4633.1-1 Temper Bead Welding and Weld Temper Bead Reinforcement of Dissimilar Metal Welds or Buttering <\/td>\n<\/tr>\n
96<\/td>\nIWA-4633.2-1 Automatic or Machine (GTAW) Temper Bead Welding of Dissimilar Metal Welds or Buttering <\/td>\n<\/tr>\n
98<\/td>\nIWA-4643.2-1 Automatic or Machine (GTAW) Temper Bead Welding of Cladding <\/td>\n<\/tr>\n
101<\/td>\nIWA-4652.4-1 Temper Bead Technique <\/td>\n<\/tr>\n
102<\/td>\nIWA-4652.4-2 Illustration of the Temper Bead Technique for Reinforcement of Existing Fillet Welds <\/td>\n<\/tr>\n
103<\/td>\nIWA-4655-1 Welding Techniques for Improper Temper Bead Spacing <\/td>\n<\/tr>\n
104<\/td>\nIWA-4655-2 Example of Weld Undercut Welding Technique <\/td>\n<\/tr>\n
105<\/td>\nIWA-4662.1-1 Depth Limitations for Underwater Welding Qualification <\/td>\n<\/tr>\n
106<\/td>\nIWA-4663.1-1 Carbon Equivalency Calculation
IWA-4662.1-2 Procedure and Performance Qualification \u2014 Position Limitations <\/td>\n<\/tr>\n
112<\/td>\nIWA-4712.2-1 Examples of Extension and Recess of Tube and Plug <\/td>\n<\/tr>\n
130<\/td>\nIWB-2411-1 Inspection Program <\/td>\n<\/tr>\n
134<\/td>\nIWB-2500-1 (B-A) Examination Category B-A, Pressure-Retaining Welds in Reactor Vessel <\/td>\n<\/tr>\n
135<\/td>\nIWB-2500-1 (B-B) Examination Category B-B, Pressure-Retaining Welds in Vessels Other Than Reactor Vessels <\/td>\n<\/tr>\n
137<\/td>\nIWB-2500-1 (B-D) Examination Category B-D, Full Penetration Welded Nozzles in Vessels <\/td>\n<\/tr>\n
138<\/td>\nIWB-2500-1 (B-F) Examination Category B-F, Pressure-Retaining Dissimilar Metal Welds in Vessel Nozzles <\/td>\n<\/tr>\n
139<\/td>\nIWB-2500-1 (B-G-1) Examination Category B-G-1, Pressure-Retaining Bolting, Greater Than 2 in. (50 mm) in Diameter <\/td>\n<\/tr>\n
142<\/td>\nIWB-2500-1 (B-G-2) Examination Category B-G-2, Pressure-Retaining Bolting, 2 in. (50 mm) and Less in Diameter <\/td>\n<\/tr>\n
143<\/td>\nIWB-2500-1 (B-J) Examination Category B-J, Pressure-Retaining Welds in Piping <\/td>\n<\/tr>\n
145<\/td>\nIWB-2500-1 (B-K) Examination Category B-K, Welded Attachments for Vessels, Piping, Pumps, and Valves <\/td>\n<\/tr>\n
147<\/td>\nIWB-2500-1 (B-L-2, B-M-2) Examination Categories B-L-2, Pump Casings; B-M-2, Valve Bodies <\/td>\n<\/tr>\n
148<\/td>\nIWB-2500-1 (B-N-1, B-N-2, B-N-3) Examination Categories B-N-1, Interior of Reactor Vessel; B-N-2, Welded Core Support Structures and Interior Attachments to Reactor Vessels; B-N-3, Removable Core Support Structures <\/td>\n<\/tr>\n
149<\/td>\nIWB-2500-1 (B-O) Examination Category B-O, Pressure-Retaining Welds in Control Rod Drive and Instrument Nozzle Housings <\/td>\n<\/tr>\n
150<\/td>\nIWB-2500-1 (B-P) Examination Category B-P, All Pressure-Retaining Components <\/td>\n<\/tr>\n
151<\/td>\nIWB-2500-1 (B-Q) Examination Category B-Q, Steam Generator Tubing <\/td>\n<\/tr>\n
152<\/td>\nIWB-2500-1 Vessel Shell Circumferential Weld Joints <\/td>\n<\/tr>\n
153<\/td>\nIWB-2500-2 Vessel Shell Longitudinal Weld Joints <\/td>\n<\/tr>\n
154<\/td>\nIWB-2500-3 Spherical Vessel Head Circumferential and Meridional Weld Joints <\/td>\n<\/tr>\n
155<\/td>\nIWB-2500-4 Shell\u2010to\u2010Flange Weld Joint <\/td>\n<\/tr>\n
156<\/td>\nIWB-2500-5 Head\u2010to\u2010Flange Weld Joint <\/td>\n<\/tr>\n
157<\/td>\nIWB-2500-6 Typical Tubesheet\u2010to\u2010Head Weld Joints <\/td>\n<\/tr>\n
158<\/td>\nIWB-2500-7(a) Nozzle in Shell or Head <\/td>\n<\/tr>\n
159<\/td>\nIWB-2500-7(b) Nozzle in Shell or Head <\/td>\n<\/tr>\n
160<\/td>\nIWB-2500-7(c) Nozzle in Shell or Head <\/td>\n<\/tr>\n
161<\/td>\nIWB-2500-7(d) Nozzle in Shell or Head <\/td>\n<\/tr>\n
162<\/td>\nIWB-2500-8 Similar and Dissimilar Metal Welds in Components, Nozzles, and Piping <\/td>\n<\/tr>\n
165<\/td>\nIWB-2500-9 Pipe Branch Connection <\/td>\n<\/tr>\n
166<\/td>\nIWB-2500-10 Pipe Branch Connection <\/td>\n<\/tr>\n
167<\/td>\nIWB-2500-11 Pipe Branch Connection <\/td>\n<\/tr>\n
168<\/td>\nIWB-2500-12(a) Stud and Threads in Flange Stud Hole <\/td>\n<\/tr>\n
169<\/td>\nIWB-2500-12(b) Pressure-Retaining Bolts <\/td>\n<\/tr>\n
170<\/td>\nIWB-2500-12(c) Pressure-Retaining Bolts <\/td>\n<\/tr>\n
171<\/td>\nIWB-2500-13 Welded Attachment <\/td>\n<\/tr>\n
172<\/td>\nIWB-2500-14 Welded Attachment <\/td>\n<\/tr>\n
173<\/td>\nIWB-2500-15 Welded Attachment <\/td>\n<\/tr>\n
174<\/td>\nIWB-2500-18 Control Rod Drive and Instrument Nozzle Housing Welds <\/td>\n<\/tr>\n
175<\/td>\nIWB-2500-20 Extent of Weld Examination <\/td>\n<\/tr>\n
179<\/td>\nIWB-3410-1 Acceptance Standards <\/td>\n<\/tr>\n
180<\/td>\nIWB-3510-1 Allowable Planar Flaws
IWB-3510-2 Allowable Laminar Flaws <\/td>\n<\/tr>\n
181<\/td>\nIWB-3510-3 Allowable Linear Flaws <\/td>\n<\/tr>\n
182<\/td>\nIWB-3512-1 Allowable Planar Flaws
IWB-3512-2 Component Thickness Versus Flaw Location <\/td>\n<\/tr>\n
183<\/td>\nIWB-3514-1 Allowable Planar Flaws <\/td>\n<\/tr>\n
184<\/td>\nIWB-3514-2 Allowable Linear Flaws <\/td>\n<\/tr>\n
185<\/td>\nIWB-3514-3 Allowable Laminar Flaws
IWB-3514-4 Allowable Linear Flaws <\/td>\n<\/tr>\n
186<\/td>\nIWB-3515-1 Allowable Planar Flaws <\/td>\n<\/tr>\n
188<\/td>\nIWB-3519.2-1 Allowable Planar Flaws <\/td>\n<\/tr>\n
189<\/td>\nIWB-3519.2-2 Allowable Planar Flaws <\/td>\n<\/tr>\n
191<\/td>\nIWB-3610-1 Characterization and Proximity Rules for Analytical Evaluation of Clad Components <\/td>\n<\/tr>\n
194<\/td>\nIWB-3662-1 Definition of Circumferential Orientation for Flaw Characterization <\/td>\n<\/tr>\n
195<\/td>\nIWB-3663-1 Reactor Vessel Head Penetration Nozzle Acceptance Criteria <\/td>\n<\/tr>\n
196<\/td>\nIWB-5230-1 Test Pressure <\/td>\n<\/tr>\n
199<\/td>\nIWC-2411-1 Inspection Program <\/td>\n<\/tr>\n
202<\/td>\nIWC-2500-1 (C-A) Examination Category C-A, Pressure-Retaining Welds in Pressure Vessels <\/td>\n<\/tr>\n
203<\/td>\nIWC-2500-1 (C-B) Examination Category C-B, Pressure-Retaining Nozzle Welds in Pressure Vessels <\/td>\n<\/tr>\n
204<\/td>\nIWC-2500-1 (C-C) Examination Category C-C, Welded Attachments for Pressure Vessels , Piping, Pumps, and Valves <\/td>\n<\/tr>\n
205<\/td>\nIWC-2500-1 (C-D) Examination Category C-D, Pressure-Retaining Bolting Greater Than 2 in. (50 mm) in Diameter <\/td>\n<\/tr>\n
206<\/td>\nIWC-2500-1 (C-F-1) Examination Category C-F-1, Pressure-Retaining Welds in Austenitic Stainless Steel or High Alloy Piping <\/td>\n<\/tr>\n
207<\/td>\nIWC-2500-1 (C-F-2) Examination Category C-F-2, Pressure-Retaining Welds in Carbon or Low Alloy Steel Piping <\/td>\n<\/tr>\n
209<\/td>\nIWC-2500-1 (C-H) Examination Category C-H, All Pressure-Retaining Components <\/td>\n<\/tr>\n
210<\/td>\nIWC-2500-1 Vessel Circumferential Welds <\/td>\n<\/tr>\n
211<\/td>\nIWC-2500-2 Typical Tubesheet\u2010to\u2010Shell Circumferential Welds <\/td>\n<\/tr>\n
212<\/td>\nIWC-2500-3 Nozzle\u2010to\u2010Vessel Welds <\/td>\n<\/tr>\n
213<\/td>\nIWC-2500-4 Nozzle\u2010to\u2010Vessel Welds <\/td>\n<\/tr>\n
217<\/td>\nIWC-2500-5 Welded Attachments <\/td>\n<\/tr>\n
218<\/td>\nIWC-2500-6(a) Pressure-Retaining Bolting <\/td>\n<\/tr>\n
219<\/td>\nIWC-2500-6(b) Pressure-Retaining Bolting <\/td>\n<\/tr>\n
220<\/td>\nIWC-2500-6(c) Pressure-Retaining Bolting <\/td>\n<\/tr>\n
221<\/td>\nIWC-2500-7 Welds in Piping <\/td>\n<\/tr>\n
223<\/td>\nIWC-2500-9 Branch Connection Welds <\/td>\n<\/tr>\n
224<\/td>\nIWC-2500-10 Pipe Branch Connection <\/td>\n<\/tr>\n
225<\/td>\nIWC-2500-11 Pipe Branch Connection <\/td>\n<\/tr>\n
226<\/td>\nIWC-2500-12 Pipe Branch Connection <\/td>\n<\/tr>\n
227<\/td>\nIWC-2500-13 Pipe Branch Connection <\/td>\n<\/tr>\n
230<\/td>\nIWC-3410-1 Acceptance Standards <\/td>\n<\/tr>\n
231<\/td>\nIWC-3510-1 Allowable Planar Flaws
IWC-3510-2 Allowable Laminar Flaws <\/td>\n<\/tr>\n
232<\/td>\nIWC-3510-3 Allowable Linear Flaws <\/td>\n<\/tr>\n
233<\/td>\nIWC-3511-1 Allowable Planar Flaws
IWC-3511-2 Allowable Linear Flaws
IWC-3513-1 Allowable Planar Flaws <\/td>\n<\/tr>\n
235<\/td>\nIWC-3514-1 Allowable Planar Flaws <\/td>\n<\/tr>\n
241<\/td>\nIWD-2411-1 Inspection Program <\/td>\n<\/tr>\n
244<\/td>\nIWD-2500-1 (D-A) Examination Category D-A, Welded Attachments for Pressure Vessels , Piping, Pumps, and Valves <\/td>\n<\/tr>\n
245<\/td>\nIWD-2500-1 (D-B) Examination Category D-B, All Pressure-Retaining Components <\/td>\n<\/tr>\n
246<\/td>\nIWD-2500-1 Welded Attachments <\/td>\n<\/tr>\n
248<\/td>\nIWD-3410-1 Acceptance Standards <\/td>\n<\/tr>\n
255<\/td>\nIWE-2411-1 Inspection Program <\/td>\n<\/tr>\n
257<\/td>\nIWE-2500-1 (E-A) Examination Category E-A, Containment Surfaces <\/td>\n<\/tr>\n
258<\/td>\nIWE-2500-1 (E-C) Examination Category E-C, Containment Surfaces Requiring Augmented Examination <\/td>\n<\/tr>\n
259<\/td>\nIWE-2500-1 (E-G) Examination Category E-G, Pressure-Retaining Bolting <\/td>\n<\/tr>\n
260<\/td>\nIWE-2500-1 Examination Areas for Moisture Barriers <\/td>\n<\/tr>\n
266<\/td>\nIWF-1300-1 Illustrations of Typical Support Examination Boundaries <\/td>\n<\/tr>\n
269<\/td>\nIWF-2410-1 Inspection Program <\/td>\n<\/tr>\n
272<\/td>\nIWF-2500-1 (F-A) Examination Category F-A, Supports <\/td>\n<\/tr>\n
279<\/td>\nIWL-2500-1 (L-A) Examination Category L\u2010A, Concrete <\/td>\n<\/tr>\n
280<\/td>\nIWL-2500-1 (L-B) Examination Category L\u2010B, Unbound Post-Tensioning System <\/td>\n<\/tr>\n
282<\/td>\nIWL-2521-1 Number of Tendons for Examination <\/td>\n<\/tr>\n
283<\/td>\nIWL-2521-2 Augmented Examination Requirements Following Post\u2010Tensioning System Repair\/Replacement Activities <\/td>\n<\/tr>\n
285<\/td>\nIWL-2525-1 Corrosion Protection Medium Analysis <\/td>\n<\/tr>\n
302<\/td>\nNIS-2 Owner\u2019s Report for Repair\/Replacement Activity <\/td>\n<\/tr>\n
304<\/td>\nOAR-1 Owner\u2019s Activity Report <\/td>\n<\/tr>\n
378<\/td>\nA-3100-1 Elliptical Flaw Models <\/td>\n<\/tr>\n
379<\/td>\nA-3210-1 Definition of x Distance Through the Wall for the Surface Flaws <\/td>\n<\/tr>\n
380<\/td>\nA-3210-2 Definition of x Distance for the Subsurface Flaw Stress Definition <\/td>\n<\/tr>\n
381<\/td>\nA-3210-3 Linearization of Stress Versus Distance Through the Wall <\/td>\n<\/tr>\n
388<\/td>\nA-3530-1 Cylindrical Flaw Geometry <\/td>\n<\/tr>\n
389<\/td>\nA-3531-1 360-deg Inside Surface Flaw Geometry <\/td>\n<\/tr>\n
390<\/td>\nA-3531-1 Coefficients for 360-deg Circumferential Inside Surface Flaw Equation <\/td>\n<\/tr>\n
394<\/td>\nA-3532-1 Coefficients for Semielliptical Circumferential Inside Surface Flaw Equations, Deepest Point (Point 1) <\/td>\n<\/tr>\n
395<\/td>\nA-3532-2 Coefficients for Semielliptical Circumferential Inside Surface Flaw Equations, Surface Point (Point 2) <\/td>\n<\/tr>\n
396<\/td>\nA-3610-1 Coefficients G0 Through G4 for Subsurface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.0 <\/td>\n<\/tr>\n
398<\/td>\nA-3610-2 Coefficients G0 Through G4 for Subsurface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.1 <\/td>\n<\/tr>\n
400<\/td>\nA-3610-3 Coefficients G0 Through G4 for Subsurface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.2 <\/td>\n<\/tr>\n
402<\/td>\nA-3610-4 Coefficients G0 Through G4 for Subsurface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.3 <\/td>\n<\/tr>\n
404<\/td>\nA-3610-5 Coefficients G0 Through G4 for Subsurface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.4 <\/td>\n<\/tr>\n
406<\/td>\nA-3610-6 Coefficients G0 Through G4 for Subsurface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.5 <\/td>\n<\/tr>\n
407<\/td>\nA-3620-1 Coefficients G0 Through G4 for Flat Plate Surface Crack With Flaw Aspect Ratio, a\/\u2113 = 0.0 <\/td>\n<\/tr>\n
408<\/td>\nA-3620-2 Coefficients G0 Through G4 for Flat Plate Surface Crack at Point 1 <\/td>\n<\/tr>\n
410<\/td>\nA-3620-3 Coefficients G0 Through G4 for Flat Plate Surface Crack at Point 2 <\/td>\n<\/tr>\n
412<\/td>\nA-3630-1 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 1), Deepest Point (Point 1) <\/td>\n<\/tr>\n
413<\/td>\nA-3630-2 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 1), Surface Point (Point 2) <\/td>\n<\/tr>\n
414<\/td>\nA-3630-3 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 5), Deepest Point (Point 1) <\/td>\n<\/tr>\n
415<\/td>\nA-3630-4 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 5), Surface Point (Point 2) <\/td>\n<\/tr>\n
416<\/td>\nA-3630-5 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 10), Deepest Point (Point 1) <\/td>\n<\/tr>\n
417<\/td>\nA-3630-6 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 10), Surface Point (Point 2) <\/td>\n<\/tr>\n
418<\/td>\nA-3630-7 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 20), Deepest Point (Point 1) <\/td>\n<\/tr>\n
419<\/td>\nA-3630-8 Coefficients Gi for Circumferential Semielliptical Inside Surface Flaw (Ri\/t = 20), Surface Point (Point 2) <\/td>\n<\/tr>\n
612<\/td>\nRRA-1 Report of Contracted Repair\/Replacement Activity <\/td>\n<\/tr>\n
650<\/td>\nINTERPRETATIONS VOLUME 63 \u2014 SECTION XI <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASME BPVC – XI -2015 BPVC Section XI-Rules for Inservice Inspection of Nuclear Power Plant Components<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASME<\/b><\/a><\/td>\n2015<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":363453,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2643],"product_tag":[],"class_list":{"0":"post-363450","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asme","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/363450","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/363453"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=363450"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=363450"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=363450"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}