{"id":396732,"date":"2024-10-20T04:26:10","date_gmt":"2024-10-20T04:26:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-12-01-2005\/"},"modified":"2024-10-26T08:13:42","modified_gmt":"2024-10-26T08:13:42","slug":"ieee-c57-12-01-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-12-01-2005\/","title":{"rendered":"IEEE C57.12.01-2005"},"content":{"rendered":"
Revision Standard – Superseded. Electrical, mechanical, and safety requirements of ventilated, non-ventilated, and sealed dry-type distribuion and power transformers or auto transformers (single and polyphase, with a voltage of 601 V or higher in the highest voltage winding) are described.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C57.12.01-2005 Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers, Including Those with Solid-Cast and\/or Resin Encapsulated Windings <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Notice to users Errata Interpretations Patents Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers, Including Those with Solid-Cast and\/or Resin Encapsulated Windings 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1.3 Word usage 2. Normative references <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3. Definitions 4. Service conditions 4.1 Usual service conditions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.2 Unusual service conditions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5. Rating data 5.1 Cooling classes of transformers <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.2 Frequency 5.3 Phases 5.4 Rated power <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.5 Voltage rating and taps 5.6 Connections <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.7 Polarity, angular displacement, and terminal marks <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.8 Impedance 5.9 Losses 5.10 Insulation levels <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.11 Temperature rise and insulation-system capability <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 5.12 Nameplates <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 6. Construction 6.1 Tank-pressure requirements 6.2 Finish of tank or enclosure 6.3 Handling provisions 6.4 Transformer accessories 6.5 Terminals 6.6 Grounding <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 6.7 Shipping 7. Short-circuit characteristics 7.1 General 7.2 Transformer categories 7.3 Short-circuit current duration and magnitude <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 7.4 System zero-sequence data <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 7.5 Application conditions requiring special consideration 7.6 Components 7.7 Base power rating of a winding <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 7.8 Effects of temperature on transformer windings during short- 7.9 Temperature limits of transformer for short-circuit conditio 7.10 Calculation of winding temperature during a short circuit <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 8. Testing and calculations 8.1 General 8.2 Test classifications 8.3 Routine, design, and other tests for transformers <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 8.4 Calculations 9. Tolerances 9.1 Ratio <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 9.2 Impedance 9.3 Losses 10. Connection of transformers for shipment <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and\/or Resin Encapsulated Windings<\/b><\/p>\n |