{"id":397954,"date":"2024-10-20T04:33:06","date_gmt":"2024-10-20T04:33:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-04-2018-2\/"},"modified":"2024-10-26T08:21:20","modified_gmt":"2024-10-26T08:21:20","slug":"ieee-c37-04-2018-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-04-2018-2\/","title":{"rendered":"IEEE C37.04-2018"},"content":{"rendered":"

Revision Standard – Active. The rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types, is covered in this standard. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Generator circuit breakers are covered by IEC\/IEEE Std 62271-37-013.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std C37.04\u2122-2018 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nContents <\/td>\n<\/tr>\n
12<\/td>\n1. Scope
2. Normative references <\/td>\n<\/tr>\n
14<\/td>\n3. Definitions, acronyms, and abbreviations
3.1 Definitions <\/td>\n<\/tr>\n
16<\/td>\n3.2 Acronyms and abbreviations <\/td>\n<\/tr>\n
17<\/td>\n4. Service conditions
4.1 Usual service conditions <\/td>\n<\/tr>\n
19<\/td>\n4.2 Unusual service conditions <\/td>\n<\/tr>\n
20<\/td>\n5. Descriptions of ratings and capabilities
5.1 General <\/td>\n<\/tr>\n
21<\/td>\n5.2 Rated maximum voltage (V) or (Ur)
5.3 Rated insulation capability <\/td>\n<\/tr>\n
23<\/td>\n5.4 Rated power-frequency (fr)
5.5 Rated continuous (normal) current (Ir) <\/td>\n<\/tr>\n
26<\/td>\n5.6 Rated short-circuit current and related required capabilities <\/td>\n<\/tr>\n
29<\/td>\n5.7 Transient recovery voltage (TRV) <\/td>\n<\/tr>\n
37<\/td>\n5.8 Rated capacitive current switching <\/td>\n<\/tr>\n
39<\/td>\n5.9 Assigned out-of-phase switching current rating <\/td>\n<\/tr>\n
40<\/td>\n5.10 Rated standard operating duty (standard duty cycle) <\/td>\n<\/tr>\n
41<\/td>\n5.11 Rated control voltage
5.12 Rated operating pressure for insulation and\/or interruption
5.13 Rated operating pressure for mechanical operation and special capabilities <\/td>\n<\/tr>\n
42<\/td>\n6. Preferred ratings
6.1 General <\/td>\n<\/tr>\n
44<\/td>\n6.2 Preferred maximum voltage and insulation capability ratings for circuit breakers <\/td>\n<\/tr>\n
48<\/td>\n6.3 Preferred ratings for class S1 circuit breakers <\/td>\n<\/tr>\n
53<\/td>\n6.4 Preferred ratings for class S2 circuit breakers for line systems below 100 kV\u00a0 <\/td>\n<\/tr>\n
59<\/td>\n6.5 Preferred ratings for circuit breakers 100 kV and above <\/td>\n<\/tr>\n
70<\/td>\n6.6 Rated reclosing times for circuit breakers
6.7 Control voltage ranges for circuit breakers <\/td>\n<\/tr>\n
72<\/td>\n6.8 Circuit breaker operation and operating endurance capabilities <\/td>\n<\/tr>\n
73<\/td>\n7. Construction and functional components
7.1 Requirements for liquids in switchgear <\/td>\n<\/tr>\n
74<\/td>\n7.2 Requirements for gases in circuit breakers
7.3 Grounding
7.4 Auxiliary and control equipment <\/td>\n<\/tr>\n
76<\/td>\n7.5 Operating mechanisms <\/td>\n<\/tr>\n
79<\/td>\n7.6 Alternative operating mechanisms <\/td>\n<\/tr>\n
80<\/td>\n7.7 Low- and high-pressure interlocking and monitoring devices
7.8 Degrees of protection by enclosures <\/td>\n<\/tr>\n
81<\/td>\n7.9 Enclosure and wiring requirements
7.10 Creepage distances
7.11 Gas and vacuum tightness <\/td>\n<\/tr>\n
82<\/td>\n7.12 Liquid tightness
7.13 Noise requirements <\/td>\n<\/tr>\n
84<\/td>\n7.14 Electromagnetic compatibility (EMC)
7.15 Vacuum interrupters and X-Ray emission
7.16 Radio influence voltage limits <\/td>\n<\/tr>\n
85<\/td>\n7.17 Requirements for terminals and bushings used on outdoor or free standing circuit breakers
7.18 Circuit breaker mechanical loading <\/td>\n<\/tr>\n
87<\/td>\nPressurized components
7.20 Pressurized systems <\/td>\n<\/tr>\n
88<\/td>\n7.21 Requirements for simultaneity of poles
8. Nameplate markings
8.1 Circuit breaker <\/td>\n<\/tr>\n
89<\/td>\n8.2 External insulation
8.3 Operating mechanism <\/td>\n<\/tr>\n
90<\/td>\n8.4 Current transformer and linear coupler nameplates <\/td>\n<\/tr>\n
91<\/td>\n8.5 Accessories
8.6 Instructions and warning signs
9. Current transformers
9.1 General
9.2 Ratings <\/td>\n<\/tr>\n
93<\/td>\n9.3 Polarity and lead marking <\/td>\n<\/tr>\n
97<\/td>\n9.4 Undervoltage trip device
9.5 Specialized Applications <\/td>\n<\/tr>\n
98<\/td>\nAnnex A (informative) Bibliography <\/td>\n<\/tr>\n
100<\/td>\nAnnex B (informative) Transient recovery voltage (TRV) <\/td>\n<\/tr>\n
114<\/td>\nAnnex C (normative) Exposure to pollution <\/td>\n<\/tr>\n
117<\/td>\nAnnex D (informative) AC arc furnace switching <\/td>\n<\/tr>\n
119<\/td>\nAnnex E (informative) Free standing current transformers <\/td>\n<\/tr>\n
121<\/td>\nAnnex F (normative) Extended electrical endurance (class E2) <\/td>\n<\/tr>\n
122<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2018<\/td>\n122<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":397962,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-397954","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/397954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/397962"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=397954"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=397954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=397954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}