{"id":403497,"date":"2024-10-20T05:06:21","date_gmt":"2024-10-20T05:06:21","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61675-12022-tc\/"},"modified":"2024-10-26T09:06:40","modified_gmt":"2024-10-26T09:06:40","slug":"bs-en-iec-61675-12022-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61675-12022-tc\/","title":{"rendered":"BS EN IEC 61675-1:2022 – TC"},"content":{"rendered":"
IEC 61675-1:2022 specifies terminology and test methods for declaring the characteristics of POSITRON EMISSION TOMOGRAPHS. POSITRON EMISSION TOMOGRAPHS detect the ANNIHILATION RADIATION of positron emitting RADIONUCLIDES by COINCIDENCE DETECTION.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30455614 <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | A-30423981 <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 4 Test methods 4.1 General 4.2.1 General <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | 4.2.2 Purpose 4.2.3 Method <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 4.2.4 Analysis <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | Figure 1 \u2013 Evaluation of FWHM <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | 4.2.5 Report Figure 2 \u2013 Evaluation of equivalent width (ew) <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 4.3 Tomographic sensitivity 4.3.1 General 4.3.2 Purpose 4.3.3 Method <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | Figure 3 \u2013 Scatter phantom configuration and position on the imaging bed <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 4.3.4 Analysis 4.3.5 Report 4.4 Scatter measurement 4.4.1 General 4.4.2 Purpose 4.4.3 Method <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 4.4.4 Analysis <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Figure 4 \u2013 Evaluation of scatter fraction <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 4.4.5 Report 4.5.1 General 4.5.2 Purpose 4.5.3 Method <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 4.5.4 Analysis <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | 4.5.5 Report 4.6 Time-of-flight resolution 4.6.1 General <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 4.6.2 Purpose 4.6.3 Method 4.6.4 Radionuclide, source distribution and data collection 4.6.5 Data processing Figure 5 \u2013 Determination of LOR distance from line source <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | 4.6.6 Analysis <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 4.6.7 Scatter and random removal 4.6.8 FWHM analysis 4.6.9 Report <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | 4.7 Image quality and quantification accuracy of source activity concentrations and PET\/CT registration accuracy 4.7.1 General 4.7.2 Purpose 4.7.3 Method <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | Figure 6 \u2013 Cross-section of body phantom <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | Figure 7 \u2013 Phantom insert with hollow spheres <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | Figure 8 \u2013 Image quality phantom and scatter phantom position for whole body scan acquisition <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | 4.7.4 Data analysis <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | Figure 9 \u2013 Placement of ROIs in the phantom background <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 4.7.5 Report <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 5 Accompanying Documents 5.1 General 5.2 Design parameters and configuration <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 5.4 Sensitivity 5.6 Count rate performance 5.7 Time-of-flight resolution 5.8 Image quality and quantification accuracy of source activity concentrations <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | Bibliography <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | Index of defined terms <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Radionuclide imaging devices. Characteristics and test conditions – Positron emission tomographs<\/b><\/p>\n |