{"id":5498,"date":"2024-10-16T18:04:23","date_gmt":"2024-10-16T18:04:23","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d5422-2009\/"},"modified":"2024-10-24T10:33:18","modified_gmt":"2024-10-24T10:33:18","slug":"astm-d5422-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d5422-2009\/","title":{"rendered":"ASTM-D5422 2009"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the use of a screw-extrusion-type capillary rheometer for the measurement of flow properties of thermoplastics and thermoplastic compounds. The measured flow properties, which are obtained through laboratory investigation, may help to describe the material behavior that occurs in factory processing.<\/p>\n
1.2 Since a screw-type capillary rheometer imparts shear energy to the material during testing, the measurements will usually differ from those obtained with a piston-type capillary rheometer (see Test Method D 3835 ).<\/p>\n
1.3 Capillary rheometer measurements for thermoplastics and thermoplastic compounds are described in Test Method D 3835 .<\/p>\n
1.4 The values stated in SI units are to be regarded as standard.<\/p>\n
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n Note<\/span> 1There is no known ISO equivalent to this standard.<\/span><\/p>\n D5422-09 Standard Test Method for Measurement of Properties of Thermoplastic Materials by Screw-Extrusion Capillary Rheometer<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology <\/td>\n<\/tr>\n\n 3<\/td>\n Summary of Test Method
Significance and Use
Interferences and Precautions <\/td>\n<\/tr>\n\n 4<\/td>\n Apparatus
Sampling and Conditioning of Samples
FIG. 1 <\/td>\n<\/tr>\n\n 5<\/td>\n Procedure
FIG. 2
TABLE 1
TABLE 2
TABLE 3 <\/td>\n<\/tr>\n\n 6<\/td>\n Calculation
Report
Precision and Bias
TABLE 4 <\/td>\n<\/tr>\n\n 7<\/td>\n Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2009<\/td>\n 7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":5499,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1179,2637],"product_tag":[],"class_list":{"0":"post-5498","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-83-080-20","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/5498","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/5499"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=5498"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=5498"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=5498"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}