{"id":69532,"date":"2024-10-17T14:06:03","date_gmt":"2024-10-17T14:06:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d7094-2004\/"},"modified":"2024-10-24T18:46:19","modified_gmt":"2024-10-24T18:46:19","slug":"astm-d7094-2004","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d7094-2004\/","title":{"rendered":"ASTM-D7094 2004"},"content":{"rendered":"

ASTM D7094-04<\/h3>\n

Historical Standard: Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester<\/h4>\n
\n

ASTM D7094<\/h4>\n

Scope<\/strong><\/p>\n

1.1 This test method covers the determination of the flash point of fuels, lube oils, solvents and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of 2.5\u00b0C per minute.<\/p>\n

1.1.1 Apparatus requiring a specimen size of 1 mL, cup size of 4 mL, and a heating rate of 5.5\u00b0C per minute must be run according to Test Method D 6450.<\/p>\n

1.2 This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available and every flash point test method, including this one, is an empirical method.<\/p>\n

Note 1\u2014Flash point values are not a constant physical chemical property of materials tested. They are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can, therefore, only be defined in terms of a standard test method and no general valid correlation can be guaranteed between results obtained by different test methods or where different test apparatus is specified.<\/p>\n

1.3 This test method utilizes a closed but unsealed cup with air injected into the test chamber.<\/p>\n

1.4 This test method is suitable for testing samples with a flash point from 35 to 225\u00b0C.<\/p>\n

Note 2\u2014Flash point determinations below 35\u00b0C and above 225\u00b0C may be performed; however, the precision has not been determined below and above these temperatures.<\/p>\n

1.5 If the users specification requires a defined flash point method other than this method, neither this method nor any other test method should be substituted for the prescribed test method without obtaining comparative data and an agreement from the specifier.<\/p>\n

1.6 The values stated in SI are to be regarded as standard. Temperatures are in degrees Celsius, pressure in kilo-Pascals.<\/p>\n

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i> For specific warning statements, see 7.2, 8.5, and 10.1.2.<\/p>\n

Keywords<\/strong><\/p>\n

continuously closed cup; flammability; flash point<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 75.080 (Petroleum products in general)<\/p>\n

DOI:<\/strong> 10.1520\/D7094-04<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology <\/td>\n<\/tr>\n
2<\/td>\nSummary of Test Method
Significance and Use
Apparatus
TABLE 1 <\/td>\n<\/tr>\n
3<\/td>\nReagents and Materials
Sampling
Quality Control Checks <\/td>\n<\/tr>\n
4<\/td>\nCalibration
Procedure
Calculation <\/td>\n<\/tr>\n
5<\/td>\nReport
Precision and Bias
Keywords
A1. APPARATUS SPECIFICATIONS
A1.1
A1.2 <\/td>\n<\/tr>\n
6<\/td>\nFIG. A1.1 <\/td>\n<\/tr>\n
7<\/td>\nFIG. A1.2 <\/td>\n<\/tr>\n
8<\/td>\nX1. APPARATUS VERIFICATION FLUIDS
X1.1 Certified Reference Material (CRM)
X1.2 Secondary Working Standard (SWS)
TABLE A1.1
TABLE X1.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D7094-04 Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2004<\/td>\n9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":69533,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-69532","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/69532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/69533"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=69532"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=69532"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=69532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}